![]() Gil Baumgartner CTCI Authenticity Chairman |
|
| Subject: P&G Valve Gapper Model 111 Instructions |
PHOTO # 1 - Insure the dial indicator plunger is free. It must move freely in and out. The plunger is spring loaded out. Some units have been idle
and stuck in position, lubrication may be required to free the plunger. The unit should be clean and lubricated.
|
|
PHOTO # 2 - |
PHOTO # 3 - Set the dial face to 0. Using the remote started switch to turn the engine you will observe the needle move from 0 to the number
that represents the gap of the valve lash. After a few revolutions of the engine the O setting may move and it can be reset or you may use the value
of the numbers the needle bounce between to determine the gap. Example 0 - 19 would be .019 or 10 -29 would also be .019. After you play with it a few
times using the remote starter switch you will understand how it works. The gapper is designed for use with the engine running at idle do not accelerate
the engine above idle. High engine rpms causes the needle to oscillate too fast which could led to the needle separating from its shaft.
|
PHOTO # 4 - When starting the engine with the gapper in place insure the carburetor is not on fast idle. When engine is running at idle the needle
oscillates between open and close position of the rocker arm to stem giving an accurate reading of the valve lash. The valve rocker gap can be adjusted
to the desired gap with the engine running at 650 rpm or slightly less. With the engine running rotate the dial face to line up with the needle pointing
to 0, as the needle point oscillates to the other end of travel observe the number, that will be the valve gap. Needle movement between the numbers is quick
and takes practice to properly read.
|
| Gil |